Jenway انگلستان
دیگر » Jenway انگلستان
اسپکتروفتومتر مدل 6705 ساخت کمپانی Jenway
6705UV/Visible Split Beam Spectrophotometer (4nm SBW)/6705B0
• Colour touch screen display
• High quality, sealed split beam optics for optimum photometric performance
• Secure multi-user operation
• Save to SD memory cards
• Enhanced productivity
• Extensive range of accessories for flexibility and improve productivity
Model 6705 covers the UV/visible range of the spectrum and has a 4nm bandwidth. All three instruments in the 67 range have modes for photometrics, spectrum scanning, multi-wavelength analysis, kinetics and quantitation, giving direct concentration results against single or multi-point calibrations. With extensive post measurement tools to ensure results are presented exactly to each users requirements the 67 series spectrophotometers also offer significant advances in data portability.
The 6705 UV/visible scanning spectrophotometer is fitted with a single 10 x 10mm cuvette holder and is supplied with 2GB of internal memory, 2GB SD memory card, 100 disposable cuvettes, instruction manual, power cable and PC software on CD ROM with interface cable.Full product specification.
Parameter 6700, 6705 and 6715 Wavelength range 320 to 1100nm (6700), 190 to 1100nm (6705, 6715) Wavelength resolution 0.1nm Wavelength accuracy ± 1.0nm Wavelength repeatability ± 0.2nm Spectral bandwidth 4nm (6700, 6705), 1.5nm (6715) Transmittance 0 to 199.9%T Absorbance - 0.300 to 3.000A Accuracy ± 0.005A at 1.0A Resolution 0.1%T, 0.001A Stability < 0.001A/h after warm-up Quantitation range - 99999 to +99999 Quantitation resolution Selectable 1, 0.1, 0.01 or 0.001 Calibration Up to 20 standards with 5 replicates of each Units mEq/l, ppm, mg/l, g/l, %, µg/ml, mg/ml, g/dl, mg/dl, µg/l, ng/l, µg/dl, M, mM, µM, U/l, mU/l, U/ml, blank Curve fit algorithms Linear, quadratic and cubic functions Multi-wavelength Up to 4 wavelengths Calculations Ratio, difference, formulae with factors Kinetics time limits 0 to 9999 seconds Calibration Standard or factor Analysis Curve details with mean rate of change plus formula of line of best fit Spectrum range Any range between 320 (6700) or 190 (6705, 6715) and 1100nm Scan speed 1500nm/min Scan interval 0.1nm Analysis Auto peaks and valleys, zoom, addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, analysis points, overlay Light source Tungsten halogen lamp (6700), Xenon lamp (6705, 6715) Configuration Secure multi-user and free access Number of users 10 users + supervisor Methods/results memory >500 on internal flash memory or removable media Removable media SD memory card Outputs USB, Centronics, Analogue Size (w x d x h) 490 x 390 x 220mm Weight 7.5kg
Dissolved oxygen probe with automatic temperature control /522023B
Glass free/epoxy bodied conductivity cell (K=0.1) /027211
Epoxy bodied conductivity cell (K=10) for use with the Enterprise 470 unit /027802
Epoxy bodied conductivity cell (K=1) for use with the Enterprise 470 unit /027298
Epoxy bodied conductivity cell (K=0.1) for use with the Enterprise 470 unit/027801