اسپکتروفتومتر مدل 7310 ساخت کمپانی Jenway

New 7310 Visible single beam spectrophotometer /731001

• Icon driven software
• Results and method saving to USB memory stick
• Autologging capabilities
• 3 year warranty
• Extensive range of accessories available

The 7310 spectrophotometer uses icon driven software and has an improved navigation system for easy and intuitive usability. This spectrophotometer features measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.

 The 7310 visible, scanning spectrophotometer is fitted with a 10x10mm cuvette holder and is supplied with a pack of 100 disposable cuvettes, instruction manual, universal power supply, USB memory stick, PC software on CD ROM and interface cable.

Full product specification.

 

Parameter

 7315

Wavelength Range

198 to 1000nm

Light source

Xenon lamp

Resolution

1nm

Accuracy

± 2nm

Repeatibility

± 0.5nm

Spectral bandwidth

 5nm

Photometric Transmittance

0 to 199.9%

Photometric Absorbance

-0.300 to 2.500

Photometric Accuracy

± 1%T, ± 0.01Abs at 1.000 Absorbance

Photometric Resolution

0.1%T, 0.001A

Concentration Range

-300 to 9999

Concentration Resolution

selectable 1/ 0.1/ 0.01/ 0.001

Concentation Calibration

Blank with a single standard or factor

Concentration Units

no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l

Concentration Factor

 0.001 to 10000

Concentration Standard

0.001 to 1000

Quantitation Range

-300 to 9999

Quantitation Resolution

selectable 1/ 0.1/ 0.01/ 0.001

Quantitation Calibration

Blank with up to 6 standards

Quantitation Curve fit algorithms

Quadratic, quadratic through zero, linear, linear through zero, interpolate

Kinetics Measurement time

2 to 9999 seconds

Kinetics Calibration

 Blank with a single standard or factor

Kinetics Display

Graphical and concentration

Kinetics Analysis

Concentration, rate of change, initial and final absorbance/:%T

Kinetics Resolution

selectable 1/ 0.1/ 0.01/ 0.001

Spectrum Range

198 to 1000nm

Spectrum Scan interval

selectable 1, 2 or 5nm

Spectrum Analysis

Absorbance or transmittance and peak and valleys

GLP

 Current time and date, user ID, instrument lock and method lock

Method storage

240

Results memory

Limited by attached mass storage device

Removable media

USB (supplied)

Outputs

USB, Analogue, RS232, Integral printer

Size (w x d x h)

 275 x 400 x 220mm

Weight

 6kg



الکترود اکسیژن محلول (DO) ساخت کمپانی Jenway
Dissolved oxygen probe with automatic temperature control /522023B
Jenway انگلستان
۰ تومان


سل کانداکتیویتی ساخت کمپانی Jenway
Ultra-pure water conductivity probe /027900
Jenway انگلستان
۰ تومان


سل کانداکتیویته ساخت کمپانی Jenway
Glass free/epoxy bodied conductivity cell (K=10)027213
Jenway انگلستان
۰ تومان


سل هدایت ساخت کمپانی Jenway
Glass free/epoxy bodied conductivity cell (K=1) /027212
Jenway انگلستان
۰ تومان


سل هدایت ( کانداکتیویتی) ساخت کمپانی Jenway
Glass free/epoxy bodied conductivity cell (K=0.1) /027211
Jenway انگلستان
۰ تومان


سل هدایت ساخت کمپانی Jenway
Glass bodied conductivity cell (K=1) /027013
Jenway انگلستان
۰ تومان


سل هدایت ساخت کمپانی Jenway
Glass bodied conductivity cell (K=0.1) /027113
Jenway انگلستان
۰ تومان


سل کانداکتیویته ساخت کمپانی Jenway
Epoxy bodied conductivity cell (K=10) for use with the Enterprise 470 unit /027802
Jenway انگلستان
۰ تومان


سل هدایت ساخت کمپانی Jenway
Epoxy bodied conductivity cell (K=1) for use with the Enterprise 470 unit /027298
Jenway انگلستان
۰ تومان


سل هدایت ساخت کمپانی Jenway
Epoxy bodied conductivity cell (K=0.1) for use with the Enterprise 470 unit/027801
Jenway انگلستان
۰ تومان
1
بعدي
آخر
(1 تا 10 از 377)

راه اندازي فروشگاه در Eforosh رايگان است

google-site-verification=_GFAcaJUXIsORHaD7UDxBL3Fkg8GK6-WoHligG1t6DU