Jenway انگلستان
دیگر » Jenway انگلستان
اسپکتروفتومتر مدل 7315 ساخت کمپانی Jenway
New 7315 UV/visible single beam spectrophotometer /731501
• Icon driven software
• Results and method saving to USB memory stick
• Autologging capabilities
• Press to read xenon lamp (7315)
• 3 year warranty including xenon lamp
• Extensive range of accessories available
The 7315 spectrophotometer uses icon driven software and has an improved navigation system for easy and intuitive usability. This spectrophotometer features measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.
The 7315 UV/visible, scanning spectrophotometer is fitted with 10x10mm cuvette holder and is supplied with a pack of 100 disposable cuvettes, instruction manual, universal power supply, USB memory stick, PC software on CD ROM and interface cable.Full product specification.
Parameter
7315 Wavelength Range
198 to 1000nm Light source
Xenon lamp Resolution
1nm Accuracy
± 2nm Repeatibility
± 0.5nm Spectral bandwidth
5nm Photometric Transmittance
0 to 199.9% Photometric Absorbance
-0.300 to 2.500 Photometric Accuracy
± 1%T, ± 0.01Abs at 1.000 Absorbance Photometric Resolution
0.1%T, 0.001A Concentration Range
-300 to 9999 Concentration Resolution
selectable 1/ 0.1/ 0.01/ 0.001 Concentation Calibration
Blank with a single standard or factor Concentration Units
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l Concentration Factor
0.001 to 10000 Concentration Standard
0.001 to 1000 Quantitation Range
-300 to 9999 Quantitation Resolution
selectable 1/ 0.1/ 0.01/ 0.001 Quantitation Calibration
Blank with up to 6 standards Quantitation Curve fit algorithms
Quadratic, quadratic through zero, linear, linear through zero, interpolate Kinetics Measurement time
2 to 9999 seconds Kinetics Calibration
Blank with a single standard or factor Kinetics Display
Graphical and concentration Kinetics Analysis
Concentration, rate of change, initial and final absorbance/:%T Kinetics Resolution
selectable 1/ 0.1/ 0.01/ 0.001 Spectrum Range
198 to 1000nm Spectrum Scan interval
selectable 1, 2 or 5nm Spectrum Analysis
Absorbance or transmittance and peak and valleys GLP
Current time and date, user ID, instrument lock and method lock Method storage
240 Results memory
Limited by attached mass storage device Removable media
USB (supplied) Outputs
USB, Analogue, RS232, Integral printer Size (w x d x h)
275 x 400 x 220mm Weight
6kg
Dissolved oxygen probe with automatic temperature control /522023B
Glass free/epoxy bodied conductivity cell (K=0.1) /027211
Epoxy bodied conductivity cell (K=10) for use with the Enterprise 470 unit /027802
Epoxy bodied conductivity cell (K=1) for use with the Enterprise 470 unit /027298
Epoxy bodied conductivity cell (K=0.1) for use with the Enterprise 470 unit/027801