K87100/K87190 دستگاه فلش پوینت - اندازه گیری نقطه احتراق بروش بسته متناسب با استاندارد ASTM D93 پنسکی مارتینز

K87100/K87190 Automatic Pensky-Martens Closed Cup Flash Point Tester


Test Method
For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing.

Features and Benefits

• Conforms to ASTM D93 and related specifications

• Simple automation routine for easy operation

• Dual flash point detection system (thermal and ionization) for measurement of samples containing water and/or silicone

• Gas or electric ignition

• Flash point operation range between 0 and 400°C

• Large viewing screen for observing test status at a distance from the unit

• Automatic barometric correction







Automatic Pensky-Martens Closed Cup Flash Point Tester
The automated Pensky-Martens flash point tester accurately determines the lowest flash point temperature of fuels, lubricating oils, and homogenous liquids (ASTM D93 A), or liquids containing suspended solids as well as liquids that tend to form a surface film during testing (ASTM D93 B). Flash point tests are simply conducted by mounting the flash cup filled with sample into the test position and selecting a pre- or user-programmed test method. A quick search method allows for determination of flash points for unknown samples and a method for asphalts is also included. The automation routines provide accurate test results, even with users inexperienced in flash point test methods. The flash point test result is automatically corrected to standard pressure (101.3 kPa). The unit is equipped with a differential Pt-100 RTD probe designed to duplicate the response time of a mercury-in-glass thermometer as per ASTM D93-02a and E1-03a. The system features multiple sensors for continually monitoring of instrument function and displaying an error message if a problem is detected. The performance of the electrical ignitor is continuously checked, and the user is notified upon the need of replacement due to either damage or the end of its useful life. The system is easily interfaced with an external PC for operation and method updates. When performing a test, the system will display the stirring speed, temperature curve (also printed out), and current test status. The system alerts the user is also alerted if the first application of the ignitor results in a flash or if no flash point is detected at the end of the test program. If a flash is not detected 30°C above the expected flash point or at 400°C, then the test is automatically aborted for safety. An easy connection to the air ventilation system or external water connection provides a quick cool down between test runs for operational efficiency.

Supervision software is included.

Specifications
Conforms to the specifications of:
ASTM D93; IP 34; ISO 2719; DIN EN 22719; NF M 07-019; JIS K2265

Electrical Requirements
115/230V 50/60Hz, Single Phase

Dimensions lxwxh,in.(cm)
10.24x21.06x19.69 (26x53.5x50)
Net Weight:
44 lbs (20kg)


Ordering Information

Catalog
Number
Product Description Electrical Requirements
K87100 Automatic Pensky-Martens Closed Cup Flash Point Tester 115V 60Hz
K87190 Automatic Pensky-Martens Closed Cup Flash Point Tester

 

230V 50Hz

 


K87100/K87190 دستگاه فلش پوینت - اندازه گیری نقطه احتراق بروش بسته متناسب با استاندارد ASTM D93 پنسکی مارتینز



K90375 دستگاه تیتراتور کارل فیشر بروش والیومتریک ساخت کمپانی کوهر آمریکا متناسب با استاندارد ASTM D789 D803 D890 ...
K90375 Volumetric Karl Fischer Titrator ASTM D789, D803, D890, D1123, D1152, D1193, D1348, D1364, D1568, D1631, D2072, D2575, D3401, D4017, D4377, D4672, D5460, D5530, E180, E203