Jenway انگلستان
دیگر » Jenway انگلستان
اسپکتروفتومتر مدل Genova Plus ساخت کمپانی Jenway
Genova Plus, Life Science Spectrophotometer /736501
• Life Science Spectrophotometer
• 5nm spectral bandwidth
• Absorbance range -0.3 to 2.5A
• Pre-programmed for DNA/RNA analysis
• Purity scan across entire wavelength range
• Pre-programmed methods for protein analysis
• Standard spectrophotometer functions
• Press to read xenon lamp
• Icon driven software
• Small footprint
• Method and result saving to USB memory stick
• 3 year warranty including xenon lamp
The new Genova Plus is a UV/visible spectrophotometer dedicated to life science analysis. This life science spectrophotometer allows the measurement of DNA concentrations and purity ratios using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The Genova Plus is pre-programmed with Bradford, Lowry, Biuret, BCA and Direct UV methods for protein analysis. The Genova Plus has an OD measurement mode enabling cell growth to be monitored by measuring absorbance at 600nm, 595nm or any other user selected wavelength. The purity scan across the entire wavelength range from 198 to 1000nm displays any distorted peaks enabling impurities to be easily identified.
This life science spectrophotometer uses icon driven software and has an improved navigation system for easy and intuitive usability. As well as the dedicated life science measurement modes this instrument can also be used as a standard spectrophotometer with measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation and kinetics.
The Genova Plus life science spectrophotometer is fitted with a micro-cuvette holder and is supplied with a 10x10mm cuvette holder, pack of 100 disposable micro-cuvettes, instruction manual, universal power supply and USB memory stick.
Full product specification.
Parameter | Genova Plus |
Wavelength Range | 198 to 1000nm |
Light source | Xenon lamp |
Wavelength Resolution | 1nm |
Wavelength Accuracy | ± 2nm |
Wavelength Repeatibility | ± 0.5nm |
Spectral bandwidth | 5nm |
Photometric Transmittance | 0 to 199.9% |
Photometric Absorbance | - 0.300 to 2.500 |
Photometric Accuracy* | ± 1%T, ± 0.01Abs at 1.000 Absorbance |
Photometric Resolution | 0.1%T, 0.001A |
Concentration/Quantitation Range | 0 to 9999 |
Concentation Calibration | Blank with a single standard or factor |
Quantitation Calibration | Blank with up to 12 standards |
Quantitation Curve fit algorithms | Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Kinetics Measurement time | 2 to 9999 seconds |
Kinetics Calibration | Blank with a single standard or factor |
Kinetics Display | Graphical and concentration |
Kinetics Analysis | Concentration, rate of change, initial and final absorbance/ %T |
Spectrum/Purity Range | 198 to 1000nm |
Scan interval | selec table 1, 2 or 5nm |
Spectrum/Purity Analysis | Absorbance or transmittance and peak and valleys |
Multi-wavelength Data Points | Up to 4 wavelengths |
Multi-wavelength Calculations | Sum, product, ratio and difference |
DNA Measurement Modes | dsDNA, ssDNA, RNA, Oligonucleotides, 260/ 280, 260/ 230, Variable ratio |
Multi-wavelength Plus Data Points | Up to 3 wavelengths plus optional reference wavelength |
Multi-wavelength Plus Calculations | Concentration and ratio |
Protein Measurement Modes | BCA, Bradford, Lowry, Biuret, Direct UV |
OD 600 Range | 0.00 E- 19 to 9.99 E+ 19 |
OD 600 Calibration | Blank with a single standard or factor |
GLP Support | Current time and date, user ID, instrument lock and method lock |
Method storage | 312 (including pre-programmed methods) |
Results memory | Limited by attached mass storage device |
Removable media | USB (supplied) |
Outputs | USB, Analogue, RS232, Integral printer |
Size (w x d x h) | 275 x 400 x 220mm |
Weight | 6kg |
Dissolved oxygen probe with automatic temperature control /522023B
Glass free/epoxy bodied conductivity cell (K=0.1) /027211
Epoxy bodied conductivity cell (K=10) for use with the Enterprise 470 unit /027802
Epoxy bodied conductivity cell (K=1) for use with the Enterprise 470 unit /027298
Epoxy bodied conductivity cell (K=0.1) for use with the Enterprise 470 unit/027801